You have no items in your shopping cart.

Below Ground Drainage

Gratings, manhole covers, inspection chambers and more - civils and below ground drainage products at C.L. Jones for North Wales building and engineering projects.
Filters
per page
GX01005
A 130mm thick wide wall chamber, in combination with the Easi-Base™ unit, provides a sealed watertight manhole system. This robust design means that the requirement for a concrete surround is eliminated.
Quick and easy installation
Watertight structure
Safe anchor lifting system (spherical head lifting system)
Greater cost savings associated with using precast concrete over a traditional system
No concrete backfill required, in accordance with ‘Sewers for Adoption’ 7th edition
More environmentally friendly than a traditional system, almost 40% less carbon emitted during the concrete casting process
Significant reduction in health and safety risks associated with using precast concrete

Please note: Wide Wall Manhole Chambers are manufactured with 3 x 45mm diameter lifting points to facilitate the safe anchor lifting system (spherical head lifting system).
GX01006
A 130mm thick wide wall chamber, in combination with the Easi-Base™ unit, provides a sealed watertight manhole system. This robust design means that the requirement for a concrete surround is eliminated.
Quick and easy installation
Watertight structure
Safe anchor lifting system (spherical head lifting system)
Greater cost savings associated with using precast concrete over a traditional system
No concrete backfill required, in accordance with ‘Sewers for Adoption’ 7th edition
More environmentally friendly than a traditional system, almost 40% less carbon emitted during the concrete casting process
Significant reduction in health and safety risks associated with using precast concrete

Please note: Wide Wall Manhole Chambers are manufactured with 3 x 45mm diameter lifting points to facilitate the safe anchor lifting system (spherical head lifting system).
PL01061
Naylor Metro Access Chamber measuring 300 x 300 x 330mm. Naylor Modular Access Chambers systems are easy to assemble, and designed to interlock at the corners with an integrated mortice and tenon taper lock system. Panels are injection moulded in 100% recycled polypropylene and designed to interlock at the corners with an integrated mortice and tenon taper lock system. The external wall is patterned such that a concrete surround will flow into voids, adding to the structural strength of the system.
Wide internal flange within the chamber enables covers and frames to fit straight onto the box, therefore direct loading is transferred evenly
Panels have trepanned holes which take electricity and utility duct sizes from 63mm to 160mm.
PL01062
Naylor Metro Access Chamber measuring 450 x 300 x 330mm. Naylor Modular Access Chambers systems are easy to assemble, and designed to interlock at the corners with an integrated mortice and tenon taper lock system. Panels are injection moulded in 100% recycled polypropylene and designed to interlock at the corners with an integrated mortice and tenon taper lock system. The external wall is patterned such that a concrete surround will flow into voids, adding to the structural strength of the system.
Wide internal flange within the chamber enables covers and frames to fit straight onto the box, therefore direct loading is transferred evenly
Panels have trepanned holes which take electricity and utility duct sizes from 63mm to 160mm.
PL01063
Naylor Merto Access Chamber measuring 450 x 450 x 330mm. Naylor Modular Access Chambers systems are easy to assemble, and designed to interlock at the corners with an integrated mortice and tenon taper lock system. Panels are injection moulded in 100% recycled polypropylene and designed to interlock at the corners with an integrated mortice and tenon taper lock system. The external wall is patterned such that a concrete surround will flow into voids, adding to the structural strength of the system.
Wide internal flange within the chamber enables covers and frames to fit straight onto the box, therefore direct loading is transferred evenly
Panels have trepanned holes which take electricity and utility duct sizes from 63mm to 160mm.
PL01064
Naylor Metro Access Chamber measuring 600 x 450 x 330mm. Naylor Modular Access Chambers systems are easy to assemble, and designed to interlock at the corners with an integrated mortice and tenon taper lock system. Panels are injection moulded in 100% recycled polypropylene and designed to interlock at the corners with an integrated mortice and tenon taper lock system. The external wall is patterned such that a concrete surround will flow into voids, adding to the structural strength of the system.
Wide internal flange within the chamber enables covers and frames to fit straight onto the box, therefore direct loading is transferred evenly
Panels have trepanned holes which take electricity and utility duct sizes from 63mm to 160mm.
PL01065
Naylor Metro Access Chamber measuring 600 x 600 x 330mm. Naylor Modular Access Chambers systems are easy to assemble, and designed to interlock at the corners with an integrated mortice and tenon taper lock system. Panels are injection moulded in 100% recycled polypropylene and designed to interlock at the corners with an integrated mortice and tenon taper lock system. The external wall is patterned such that a concrete surround will flow into voids, adding to the structural strength of the system.
Wide internal flange within the chamber enables covers and frames to fit straight onto the box, therefore direct loading is transferred evenly
Panels have trepanned holes which take electricity and utility duct sizes from 63mm to 160mm.
PB01020
Adaptor Coupling MAC is ideal for the external connection of all pipe systems
with different outside diameters. It connects all plain ended pipes with different
outside diameters and materials. It can be used for applications above and below ground as well as inside and outside of buildings. When changing nominal diameters, the flow direction needs consideration.

• Adaptor for different outside diameters
• For above and below ground
• External compression seal
• Resistant to 0.6 bar

Manufacturer:MISSION RUBBER
Pressure Tightness:0.6 bar wasser / -0.3 bar vacuum
Jetting Resistance:120 bar
Sealing Material:EPDM rubber with lock in place profile according to BS EN 681-1
Stainless Steel:AISI 304/1.4301, alternatively AISI 316/1.4404 according to BS EN 10088-2
Temperature Resistance:-40°C to +120°C, temporary max. temperature +160°C
Standard/Approval:BS EN 16397-2, CE16
PB01021
Adaptor Coupling MAC is ideal for the external connection of all pipe systems
with different outside diameters. It connects all plain ended pipes with different
outside diameters and materials. It can be used for applications above and below ground as well as inside and outside of buildings. When changing nominal diameters, the flow direction needs consideration.

• Adaptor for different outside diameters
• For above and below ground
• External compression seal
• Resistant to 0.6 bar

Manufacturer:MISSION RUBBER
Pressure Tightness:0.6 bar wasser / -0.3 bar vacuum
Jetting Resistance:120 bar
Sealing Material:EPDM rubber with lock in place profile according to BS EN 681-1
Stainless Steel:AISI 304/1.4301, alternatively AISI 316/1.4404 according to BS EN 10088-2
Temperature Resistance:-40°C to +120°C, temporary max. temperature +160°C
Standard/Approval:BS EN 16397-2, CE16
PB01022
Adaptor Coupling MAC is ideal for the external connection of all pipe systems
with different outside diameters. It connects all plain ended pipes with different
outside diameters and materials. It can be used for applications above and below ground as well as inside and outside of buildings. When changing nominal diameters, the flow direction needs consideration.

• Adaptor for different outside diameters
• For above and below ground
• External compression seal
• Resistant to 0.6 bar

Manufacturer:MISSION RUBBER
Pressure Tightness:0.6 bar wasser / -0.3 bar vacuum
Jetting Resistance:120 bar
Sealing Material:EPDM rubber with lock in place profile according to BS EN 681-1
Stainless Steel:AISI 304/1.4301, alternatively AISI 316/1.4404 according to BS EN 10088-2
Temperature Resistance:-40°C to +120°C, temporary max. temperature +160°C
Standard/Approval:BS EN 16397-2, CE16
PB01023
Adaptor Coupling MAC is ideal for the external connection of all pipe systems
with different outside diameters. It connects all plain ended pipes with different
outside diameters and materials. It can be used for applications above and below ground as well as inside and outside of buildings. When changing nominal diameters, the flow direction needs consideration.

• Adaptor for different outside diameters
• For above and below ground
• External compression seal
• Resistant to 0.6 bar

Manufacturer:MISSION RUBBER
Pressure Tightness:0.6 bar wasser / -0.3 bar vacuum
Jetting Resistance:120 bar
Sealing Material:EPDM rubber with lock in place profile according to BS EN 681-1
Stainless Steel:AISI 304/1.4301, alternatively AISI 316/1.4404 according to BS EN 10088-2
Temperature Resistance:-40°C to +120°C, temporary max. temperature +160°C
Standard/Approval:BS EN 16397-2, CE16
PB01024
Adaptor Coupling MAC is ideal for the external connection of all pipe systems
with different outside diameters. It connects all plain ended pipes with different
outside diameters and materials. It can be used for applications above and below ground as well as inside and outside of buildings. When changing nominal diameters, the flow direction needs consideration.

• Adaptor for different outside diameters
• For above and below ground
• External compression seal
• Resistant to 0.6 bar

Manufacturer:MISSION RUBBER
Pressure Tightness:0.6 bar wasser / -0.3 bar vacuum
Jetting Resistance:120 bar
Sealing Material:EPDM rubber with lock in place profile according to BS EN 681-1
Stainless Steel:AISI 304/1.4301, alternatively AISI 316/1.4404 according to BS EN 10088-2
Temperature Resistance:-40°C to +120°C, temporary max. temperature +160°C
Standard/Approval:BS EN 16397-2, CE16
PB01025
Drainage Coupling MDC is ideal solution for the external connection of all pipe systems with same outside diameters
The Drainage Coupling MDC connects all plain ended pipes with same outside diameters and materials. It can be used for applications above and below ground as well as inside and outside of buildings.

• Coupling for same outside diameters
• For above and below ground
• External compression seal
• Resistant to 0.6 bar

Manufacturer:MISSION RUBBER
Pressure Tightness:0.6 bar wasser / -0.3 vacuum
Jetting Resistance:120 bar
Sealing Material:EPDM or Nitrile (NBR) rubber with lock in place profile according to BS EN 681-1
Stainless Steel:AISI 304/1.4301, alternatively AISI 316/1.4404 according to BS EN 10088-2
Temperature Resistance:-40°C to +120°C, temporary max. temperature +160°C
Standard/Approval: BS EN 16397-2, CE16
PB01026
Drainage Coupling MDC is ideal solution for the external connection of all pipe systems with same outside diameters
The Drainage Coupling MDC connects all plain ended pipes with same outside diameters and materials. It can be used for applications above and below ground as well as inside and outside of buildings.

• Coupling for same outside diameters
• For above and below ground
• External compression seal
• Resistant to 0.6 bar

Manufacturer:MISSION RUBBER
Pressure Tightness:0.6 bar wasser / -0.3 vacuum
Jetting Resistance:120 bar
Sealing Material:EPDM or Nitrile (NBR) rubber with lock in place profile according to BS EN 681-1
Stainless Steel:AISI 304/1.4301, alternatively AISI 316/1.4404 according to BS EN 10088-2
Temperature Resistance:-40°C to +120°C, temporary max. temperature +160°C
Standard/Approval: BS EN 16397-2, CE16
PB01027
Standard Coupling MSC is an ideal solution for the external connection of all pipe systems with different or same outside diameters. Suitable for applications above and below ground as well as inside and outside of buildings. It can connect all plain ended pipes within same or different dimensions and is compensating differences in outside diameters of max. 12 mm. Differences in outside diameters of more than 12 mm will require the use of bushes.

• For all pipe materials
• For above and below ground
• For usage with bushes
• Resistant to 2.5 bar

Manufacturer:MISSION RUBBER (UK
Pressure Tightness:2.5 bar wasser / -0.3 bar vacuum
Jetting Resistance:120 bar
Corrosion Resistance:TOX-Technology
Sealing Material:EPDM or Nitrile (NBR) rubber with lock in place profile according to BS EN 681-1
Stainless Steel:AISI 304/1.4301, alternatively AISI 316/1.4404 according to BS EN 10088-2
Temperature Resistance:-40°C to +120°C, temporary max. temperature +160°C
Standard/Approval:BS EN 16397-2, CE16
PB01028
Standard Coupling MSC is an ideal solution for the external connection of all pipe systems with different or same outside diameters. Suitable for applications above and below ground as well as inside and outside of buildings. It can connect all plain ended pipes within same or different dimensions and is compensating differences in outside diameters of max. 12 mm. Differences in outside diameters of more than 12 mm will require the use of bushes.

• For all pipe materials
• For above and below ground
• For usage with bushes
• Resistant to 2.5 bar

Manufacturer:MISSION RUBBER (UK
Pressure Tightness:2.5 bar wasser / -0.3 bar vacuum
Jetting Resistance:120 bar
Corrosion Resistance:TOX-Technology
Sealing Material:EPDM or Nitrile (NBR) rubber with lock in place profile according to BS EN 681-1
Stainless Steel:AISI 304/1.4301, alternatively AISI 316/1.4404 according to BS EN 10088-2
Temperature Resistance:-40°C to +120°C, temporary max. temperature +160°C
Standard/Approval:BS EN 16397-2, CE16
GH05151
320mm diameter circle opening on 380mm square to round infill with 83mm depth. Galvanised steel cover and frame with 5 tonne load.
GH05152
450mm diameter circle opening on square to round infill with 83mm depth. Galvanised steel cover and polypropylene frame with 5 tonne load.
PL01035
JRT Radon sump unit with 4 x 110mm connections
PL01015
TypeA-P light duty polypropyleme hinged solid top stop tap box, measuring 152 x 120 x 75mm. Manufactured to BS 5834 Part 2. Suitable for areas with pedestrian access only.